{"id":66,"date":"2026-09-28T12:10:35","date_gmt":"2026-09-28T12:10:35","guid":{"rendered":"https:\/\/www.velonexchemicals.com\/blog\/?p=66"},"modified":"2026-10-09T05:00:06","modified_gmt":"2026-10-09T05:00:06","slug":"alum-vs-pac-coagulant","status":"publish","type":"post","link":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/","title":{"rendered":"Alum vs PAC (Poly Aluminium Chloride): Which Coagulant Suits Your Plant, and How to Decide With a Jar Test"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Choosing between aluminium sulphate (commonly known as alum) and poly aluminium chloride (PAC) is one of the most consequential decisions an effluent treatment plant (ETP), water treatment plant (WTP), or municipal water utility operator faces. Both of these chemicals function as primary coagulants designed to clarify turbid, cloudy water by clumping together microscopic suspended impurities so they settle rapidly out of the liquid stream. However, the underlying chemical mechanisms, dosing volumes, alkalinity consumption, operational pH spans, and post treatment sludge characteristics differ sharply between the two.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Many plant engineers and procurement managers evaluate coagulant decisions purely on purchase invoice figures, looking strictly at the upfront price per bag or per metric ton. While alum presents a lower purchase price at the factory gate, poly aluminium chloride brings a high active concentration and pre engineered polymer chains that frequently minimize secondary chemical spending, lower total sludge cake disposal weight, and stabilize compliance under sudden incoming water shocks. Making the correct selection requires a complete view of raw water characteristics, plant design constraints, running costs, and laboratory validation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Coagulation Mechanism Explained<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Raw incoming water, whether drawn from an open river reservoir, a deep industrial borewell, or an industrial process wash line, is laden with colloidal contaminants. These particles encompass fine silts, clays, natural organic materials, microscopic debris, and suspended oils.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Colloidal impurities remain suspended indefinitely because their surface chemistry carries net negative electrical charges. When two negatively charged colloidal particles approach each other inside a moving fluid, their matching electrical fields generate electrostatic repulsion forces that prevent them from colliding. The liquid remains turbid, murky, or colored because gravity cannot overcome these repulsive forces on such small particles.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The fundamental objective of chemical coagulation is to neutralize these negative surface charges, compress the electrical double layer surrounding each suspended particle, and enable the van der Waals forces of attraction to take control. Once charge neutralization occurs, gentle agitation allows the uncharged or minimally charged particles to collide, stick together, and grow into visible agglomerations called flocs. These flocs possess sufficient mass and density to settle out by gravity in clarifiers, lamella separators, or dissolved air flotation units.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Both alum and poly aluminium chloride deliver positively charged aluminium species to accomplish this particle destabilization, but they introduce these ions through fundamentally distinct chemical pathways.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Each Coagulant Works, in Plain Terms<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Aluminium Sulphate (Alum)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Alum is an inorganic salt consisting of aluminium sulphate octadecahydrate. When solid alum dissolves in water, it dissociates completely into trivalent aluminium ions and sulphate anions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The bare aluminium ion is unstable in aqueous environments and instantly undergoes rapid hydrolysis reactions with water molecules. During this hydrolysis sequence, the aluminium ion binds with water molecules and progressively releases hydrogen ions into the surrounding solution. This sequence creates a series of monomeric and intermediate aluminium hydroxide complexes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because this stepwise hydrolysis reaction releases significant volumes of free hydrogen ions, it consumes the naturally occurring bicarbonate alkalinity present in the raw water. If the water source lacks natural bicarbonate alkalinity, this free acid generation causes the process water pH to drop dramatically. Once the pH drops below the optimal threshold, coagulation slows down, floc formation collapses, and soluble aluminium ions remain dissolved in the treated water rather than precipitating into solid flocs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Consequently, conventional alum dosing almost always demands careful monitoring of baseline alkalinity, alongside regular supplementary dosing of basic conditioning chemicals such as hydrated lime, sodium hydroxide (caustic soda), or sodium carbonate (soda ash) to stabilize the reaction environment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Poly Aluminium Chloride (PAC)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Poly aluminium chloride represents an advanced generation of pre hydrolyzed inorganic coagulants. It is manufactured by reacting aluminium chloride with controlled alkaline reagents under regulated temperature and pressure conditions. This controlled pre reaction binds aluminium atoms together into polynuclear cationic polymers before the product ever reaches your water treatment facility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because PAC has already completed a major portion of its hydrolysis reaction during industrial manufacturing, its aluminium atoms are locked into large, highly charged polymeric complexes, such as the Al13 Keggin ion structure. When PAC enters turbid water, it does not need to complete a lengthy, acid releasing hydrolysis sequence. Instead, its preformed high charge polymers neutralize the negative colloidal surface charges almost instantaneously through rapid electrostatic patch mechanisms and charge bridging.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because PAC releases far fewer hydrogen ions during in plant dosing, it consumes only a small fraction of the raw water&#8217;s natural alkalinity. The water retains its baseline pH without steep drops. For plant operators, this characteristic preserves process stability, eliminates or drastically reduces the need for supplemental lime or caustic soda dosing, and ensures reliable flocculation even in low alkalinity or cold water conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Side by Side Comparison: Alum vs PAC<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The fundamental physical, chemical, and operational differences between aluminium sulphate and poly aluminium chloride can be summarized across core plant parameters:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Feature<\/td><td>Aluminium Sulphate (Alum)<\/td><td>Poly Aluminium Chloride (PAC)<\/td><\/tr><tr><td>Active Content (Al2O3 equivalent)<\/td><td>16% to 17%<\/td><td>28% to 30% (solid\/powder grade)<\/td><\/tr><tr><td>Operational pH Range<\/td><td>Narrow (6.0 to 7.5)<\/td><td>Broad (5.5 to 8.5, functional up to 9.0)<\/td><\/tr><tr><td>Typical Working Dosage Requirement<\/td><td>Higher (typically 20 to 60 ppm)<\/td><td>Lower (typically 30% to 50% less active chemical)<\/td><\/tr><tr><td>Consumption of Process Alkalinity<\/td><td>High (frequently requires lime or caustic addition)<\/td><td>Very low (conserves baseline raw water alkalinity)<\/td><\/tr><tr><td>Rate of Floc Formation and Settling<\/td><td>Moderate floc formation; slower settling speed<\/td><td>Rapid floc formation; dense flocs with high settling velocity<\/td><\/tr><tr><td>Total Sludge Mass and Volume<\/td><td>High volume, high moisture retention<\/td><td>30% to 40% less sludge volume with superior dewatering<\/td><\/tr><tr><td>Performance in Cold Temperature Water<\/td><td>Hydrolysis slows significantly in cold water<\/td><td>Consistently effective across diverse temperature swings<\/td><\/tr><tr><td>Purchase Cost per Kilogram<\/td><td>Lower purchase price per bag<\/td><td>Higher purchase price per bag<\/td><\/tr><tr><td>Physical Supply Format<\/td><td>Lumps, kibbled pieces, or coarse tan powder<\/td><td>Fine light yellow powder or concentrated clear liquid<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">When Alum Wins<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Despite the technical benefits of polymeric coagulants, traditional aluminium sulphate remains one of the most widely consumed water treatment chemicals across the globe. Alum delivers predictable, cost effective clarification when applied in plants that match its operating profile:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Stable, Predictable Raw Water Quality<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Facilities that treat consistent groundwater extracted from deep borewells, or those drawing water from massive, well regulated municipal reservoirs, rarely experience sudden turbidity shocks. In these environments, incoming turbidity and organic levels remain uniform across weeks and months. Because the raw water presents no rapid swings, a steady, dialed in dose of alum provides reliable particle removal day after day.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. High Natural Baseline Alkalinity<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When the source water possesses sufficient natural bicarbonate buffering capacity, usually above 100 mg\/L as calcium carbonate, the acid generated by alum hydrolysis does not depress the pH below the critical 6.0 threshold. The natural buffering capacity absorbs the released hydrogen ions automatically, enabling complete coagulation without the added operating expense of installing and maintaining secondary caustic or lime dosing skids.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Tight Chemical Procurement Budgets<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Municipal tenders, regional water boards, and industrial facilities operating under strict quarterly chemical spending ceilings often favor alum due to its low unit acquisition cost. Purchasing standard alum provides the lowest initial price per metric ton, which helps purchasing managers align with fixed procurement targets when upfront cash flow is a key concern.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Established Dosing Infrastructure<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Decades old clarification systems are often designed around solid alum handling. Such facilities already possess large concrete dissolving pits, dedicated mechanical agitators, stainless steel dissolving baskets, and metering systems calibrated specifically for alum solutions. Transitioning away from this equipment requires recalibrating operational procedures, training staff, and updating safety protocols, making continued alum usage the path of least resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For industrial plants situated across Tamil Nadu and neighboring industrial corridors, consistent non ferric alum in standard 25 kg and 50 kg moisture resistant bags can be procured directly from <a href=\"https:\/\/www.velonexchemicals.com\/alum\">Velonex Chemicals Alum Supply<\/a>, distributed from established warehousing facilities in Redhills, Chennai.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When PAC Wins<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Operating conditions in industrial effluent treatment plants and modern municipal plants frequently exceed the capabilities of conventional aluminium sulphate. Poly aluminium chloride proves superior across several demanding scenarios:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Sudden Turbidity Spikes and Monsoon Runoff<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Facilities that draw surface water from active rivers, open rainwater collection reservoirs, or industrial storm drains experience sudden turbidity spikes during heavy rains. While alum struggles to form flocs quickly under sudden turbidity spikes, PAC responds almost instantaneously. Its preformed, high charge polymer chains neutralize surging solids loads without requiring massive increases in chemical volume, protecting clarifiers from solids washouts.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Soft, Low Alkalinity Source Water<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Treating soft river water, demineralized process streams, or textile wash rinse effluent with alum presents persistent operational challenges. Because these water sources contain very little natural mineral alkalinity, dosing alum rapidly drops the pH into an acidic zone where coagulation fails. PAC consumes minimal alkalinity, allowing the water to maintain a stable, compliant pH and eliminating the operational expense, safety hazards, and pump maintenance associated with dosing supplemental lime or caustic soda.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Low Temperature Winter Clarification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The chemical hydrolysis of standard alum is strongly endothermic, meaning the reaction rate drops significantly as water temperatures decline. During colder seasons, alum flocs form very slowly, become fragile, and often shear apart under minimal hydraulic turbulence, leading to carryover that blinds downstream sand filters. PAC relies on pre hydrolyzed structures whose charge neutralization is largely independent of water temperature, making it reliable in winter and cold process conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Overburdened Clarifiers and Tight Footprints<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Many industrial plants face production expansions that force higher effluent volumes through existing clarifiers without room for new civil construction. PAC forms dense, high mass flocs that settle up to twice as fast as fluffy alum flocs. This settling velocity allows secondary clarifiers, lamella plate settlers, and tube settlers to handle higher surface hydraulic loading rates without floc carryover into the clean water collection launders.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. High Hazardous Sludge Disposal Costs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In industrial wastewater treatment plants, chemical sludge handling is one of the highest operating expenses. Alum produces a voluminous, gelatinous aluminium hydroxide precipitate that traps water molecules within its matrix, making it difficult to dewater in filter presses or decanters. PAC produces a denser, lower volume sludge that dewaters easily, resulting in drier filter press cakes and reducing sludge mass by 30% to 40%. For plants paying hazardous waste disposal fees per metric ton of sludge, these weight reductions deliver substantial savings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To explore compatible coagulants, flocculants, and specialty wastewater products, plant managers can reference the <a href=\"https:\/\/www.velonexchemicals.com\/\">Velonex Chemicals Product Directory<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Decide With Data: A 6 Jar Test Step by Step<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Never switch coagulants or alter chemical dosing regimes based entirely on technical datasheets or theoretical calculations. Raw water chemistry contains unique balances of natural organic matter, zeta potential, mineral hardness, and background conductivity that can only be evaluated through on site bench testing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A standard 6 jar test apparatus allows operators to simulate rapid flash mixing, gentle flocculation, and quiescent settling across multiple chemical dosage concentrations simultaneously.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Required Equipment and Materials<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>One standard laboratory 6 paddle jar test machine with digital speed control and illuminated base<\/li>\n\n\n\n<li>Six matching 1,000 mL or 2,000 mL glass beakers<\/li>\n\n\n\n<li>Precision analytical balance capable of measuring down to 0.01 grams<\/li>\n\n\n\n<li>Calibrated nephelometric turbidity meter (NTU)<\/li>\n\n\n\n<li>Calibrated digital pH meter with temperature compensation<\/li>\n\n\n\n<li>Graduated volumetric pipettes (1 mL, 5 mL, and 10 mL)<\/li>\n\n\n\n<li>20 liters of fresh, representative raw influent water<\/li>\n\n\n\n<li>High purity laboratory distilled or demineralized water<\/li>\n\n\n\n<li>Samples of dry commercial alum and dry commercial PAC powder<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 1: Baseline Water Analysis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Collect a fresh sample of raw influent water directly ahead of your plant&#8217;s primary flash mixing chamber. Do not let the sample sit for hours before testing, as biological changes, temperature shifts, and settling will alter its baseline characteristics. Immediately measure and record the baseline parameters:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Initial Turbidity (NTU)<\/li>\n\n\n\n<li>Initial pH<\/li>\n\n\n\n<li>Water Temperature (\u00b0C)<\/li>\n\n\n\n<li>Total Alkalinity (mg\/L as CaCO3)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 2: Preparing Standard Stock Solutions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To achieve micro level dosing in a bench scale beaker, prepare fresh 1.0% weight by volume (w\/v) chemical stock solutions:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Weigh exactly 1.00 gram of commercial alum powder on the analytical balance.<\/li>\n\n\n\n<li>Transfer the alum powder into a 100 mL volumetric flask, fill to the calibration line with distilled water, and mix until dissolved.<\/li>\n\n\n\n<li>Repeat this exact process in a separate 100 mL volumetric flask using 1.00 gram of dry PAC powder.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Using this 1.0% solution:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Adding 1.0 mL of stock solution to a 1,000 mL water sample yields an exact coagulant dosage of 10 mg\/L (10 ppm).<\/li>\n\n\n\n<li>Adding 2.0 mL yields 20 ppm, 3.0 mL yields 30 ppm, and so forth.<\/li>\n\n\n\n<li>Prepare these stock solutions fresh for each test series, as diluted coagulant solutions hydrolyze and lose activity over time.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 3: Setting Up the Test Gradient<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fill each of the six jar test beakers with 1,000 mL of your raw water sample and place them securely beneath the stirrer paddles. Lower the paddles into the beakers so they sit equidistant from the beaker walls and suspended roughly one third of the liquid depth from the bottom.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Establish a dosage range across the six jars to bracket your expected operating envelope. A standard initial screening gradient is:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Jar 1: 10 ppm (1.0 mL stock solution)<\/li>\n\n\n\n<li>Jar 2: 20 ppm (2.0 mL stock solution)<\/li>\n\n\n\n<li>Jar 3: 30 ppm (3.0 mL stock solution)<\/li>\n\n\n\n<li>Jar 4: 40 ppm (4.0 mL stock solution)<\/li>\n\n\n\n<li>Jar 5: 50 ppm (5.0 mL stock solution)<\/li>\n\n\n\n<li>Jar 6: 60 ppm (6.0 mL stock solution)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pre load these precise volumes of chemical stock into clean syringes or small test vials so they can be injected into all six jars simultaneously.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 4: Rapid Flash Mixing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Power on the jar test apparatus and bring the paddle rotation speed up to 120 to 150 RPM. Inject the pre measured coagulant doses into the corresponding jars at the exact same moment. Maintain this rapid agitation for 60 seconds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rapid flash mixing provides the high hydraulic shear needed to disperse the coagulant throughout the volume and initiate instantaneous charge neutralization across the colloidal particles before secondary reactions take place.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 5: Flocculation Stage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Once 60 seconds of flash mixing concludes, immediately step down the paddle speed to a slow, gentle 30 to 40 RPM. Maintain this slow mixing speed for 15 to 20 minutes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During this slow flocculation stage, monitor each beaker closely and record:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The exact elapsed time when pin flocs first become visible in each jar.<\/li>\n\n\n\n<li>The relative visual density, size, and structure of the flocs as they aggregate.<\/li>\n\n\n\n<li>Any signs of floc shearing, where high agitation breaks fragile flocs apart.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 6: Quiescent Settling Phase<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When the flocculation period ends, shut off the drive motor, raise the paddles carefully out of the beakers without disturbing the water, and start a timer. Allow the beakers to rest undisturbed for 20 to 30 minutes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Observe the settling behavior:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Note the settling velocity (measure how many centimeters the floc blanket drops per minute).<\/li>\n\n\n\n<li>Observe the clarity of the supernatant water above the settling sludge blanket.<\/li>\n\n\n\n<li>Inspect the settled sludge layer at the bottom of the beaker for compactness, noting whether it forms a tight pellet or a loose, fluffy layer.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Step 7: Sampling and Analytical Verification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After 20 to 30 minutes of quiescent settling, collect water samples from each beaker. Draw the sample using a clean syringe or sample tube positioned roughly 2 inches (5 cm) below the water surface, ensuring you do not pull settled sludge off the bottom or skim floating material from the surface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Test each collected sample for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Final Turbidity (record the lowest NTU achieved)<\/li>\n\n\n\n<li>Final pH (confirm the reading remains within compliant discharge or downstream process ranges)<\/li>\n\n\n\n<li>Sludge Depth (measure the height of settled solids in millimeters)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Once this initial run is completed, repeat the entire 6 jar sequence using the competing coagulant under identical raw water, temperature, and mixing conditions. Plotting the resulting residual turbidity values against chemical dosage yields a clear performance curve that identifies the optimal coagulant and its exact dosage window.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cost per KL Treated: Formula and Template<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comparing coagulants purely on the purchase price per kilogram from vendor quotation sheets is a common oversight in industrial procurement. Because poly aluminium chloride typically requires a lower active dosage than alum, and because alum often requires secondary alkaline additions to prevent pH drops, the true operational cost must be evaluated on the total chemical expense required to clarify one kilolitre (KL or 1,000 litres) of water.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cost per KL Formula<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To calculate your facility&#8217;s real chemical cost per kilolitre of treated water, plug your site specific jar test doses and negotiated vendor prices into the following formula:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PrimaryCoagulantCostperKL=CoagulantDose(inmg\/Lorppm)VendorCoagulantPriceperkg1000<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SupplementalAlkaliCostperKL=AlkaliDose(inmg\/Lorppm)VendorAlkaliPriceperkg1000<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TotalChemicalCostperKL=PrimaryCoagulantCostperKL+SupplementalAlkaliCostperKL<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 mg\/L (ppm) equals 1 gram per cubic meter (1 KL).<\/li>\n\n\n\n<li>Dividing the product by 1,000 converts grams into kilograms to align directly with commercial invoice rates.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Plant Evaluation Template<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Plant managers can run their site data through this calculation framework using their specific plant variables:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Calculation Parameter<\/td><td>Variable Symbol<\/td><td>Alum Evaluation<\/td><td>PAC Evaluation<\/td><\/tr><tr><td>Daily Water Flow (KL\/day)<\/td><td>V<\/td><td>Enter daily plant volume<\/td><td>Enter daily plant volume<\/td><\/tr><tr><td>Optimal Jar Test Dose (mg\/L)<\/td><td>Dcoag<\/td><td>Insert optimal Alum dose<\/td><td>Insert optimal PAC dose<\/td><\/tr><tr><td>Coagulant Price per kg<\/td><td>Pcoag<\/td><td>Insert current Alum price quote<\/td><td>Insert current PAC price quote<\/td><\/tr><tr><td>Primary Coagulant Cost per KL<\/td><td>C1=DcoagPcoag1000<\/td><td>Calculate baseline Alum spend<\/td><td>Calculate baseline PAC spend<\/td><\/tr><tr><td>Auxiliary Alkali Dose needed for pH (mg\/L)<\/td><td>Dalk<\/td><td>Insert required Lime or Caustic dose<\/td><td>Insert required Lime or Caustic dose (often 0)<\/td><\/tr><tr><td>Alkali Price per kg<\/td><td>Palk<\/td><td>Insert local alkali price quote<\/td><td>Insert local alkali price quote<\/td><\/tr><tr><td>Auxiliary Alkali Cost per KL<\/td><td>C2=DalkPalk1000<\/td><td>Calculate alkali spend<\/td><td>Calculate alkali spend<\/td><\/tr><tr><td>Total Clarification Cost per KL<\/td><td>Ctotal=C1+C2<\/td><td>Sum for total Alum cost per KL<\/td><td>Sum for total PAC cost per KL<\/td><\/tr><tr><td>Total Daily Chemical Cost<\/td><td>Costday=CtotalV<\/td><td>Total Alum daily budget<\/td><td>Total PAC daily budget<\/td><\/tr><tr><td>Projected Annual Chemical Spend<\/td><td>Costyear=Costday365<\/td><td>Total Alum annual budget<\/td><td>Total PAC annual budget<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Evaluating your site numbers through this formula clarifies the true operating cost. In many industrial wastewater plants, the lower dose rate of PAC and the complete elimination of alkali conditioning can outweigh the higher per kilogram purchase price, even before factoring in secondary savings in filter press running hours and sludge disposal volume.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Is PAC better than alum?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PAC is not universally superior for every treatment facility, but it offers clear operational advantages in many applications. PAC operates across a broader pH spectrum, forms denser and faster settling flocs, performs reliably in low temperature water, and produces roughly 30% to 40% less sludge volume than aluminium sulphate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, for plants that treat raw water with consistent quality, steady temperatures, and abundant natural alkalinity, conventional alum provides reliable, cost effective clarification at a lower chemical acquisition cost.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can alum and PAC be used together?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Directly blending commercial alum and PAC together inside a single storage or chemical dissolving tank is not advisable. The differences in chemical basicity, ionic strength, and pre hydrolysis levels cause unpredictable reactions that precipitate gelatinous aluminium hydrates, clogging feed pumps, suction lines, and injection quills.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, certain multi stage treatment designs apply alum and PAC sequentially at separate physical dosing junctions. For example, a plant may use alum in a primary clarifier to remove high bulk suspended solids, followed downstream by a low PAC dose to sweep fine pin flocs before final filtration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the alum dose per 1000 litres?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For typical municipal drinking water and moderate surface water treatment, the standard alum dose ranges between 15 and 45 grams per 1,000 litres of water (equivalent to 15 to 45 mg\/L or ppm).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In contrast, heavily contaminated industrial wastewater, electroplating rinse effluents, or surface runoffs with severe organic loads can require anywhere from 50 to 120 grams per 1,000 litres. Because every water stream possesses unique particulate charges and buffer chemistry, the precise dose should always be validated through on site jar testing before adjusting plant feed pumps.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What pH is best for alum?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Aluminium sulphate functions within an optimal pH window of 6.0 to 7.5.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the process water drops below pH 6.0, the hydrolysis sequence remains incomplete, floc formation stalls, and residual soluble aluminium ions pass through the clarifier into the treated water. If the process water rises above pH 7.8, the precipitated aluminium hydroxide flocs begin to redissolve as amphoteric aluminate ions, causing treated water turbidity to rise and blinding downstream sand filter beds.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is PAC more expensive per kg?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Poly aluminium chloride commands a higher price per kilogram because its manufacturing process is more complex and capital intensive than that of standard alum.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While alum is produced through a simple digestion of bauxite ore with sulphuric acid, PAC requires reacting aluminium chloride solutions with controlled alkaline agents under pressurized, high temperature reactor conditions. This process creates stable, pre polymerized polynuclear aluminium clusters with an active aluminium oxide content of 28% to 30%, compared to only 16% to 17% in standard alum. This higher concentration and enhanced charge density provide more active flocculating power per kilogram of dry chemical.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Choosing between aluminium sulphate (commonly known as alum) and poly aluminium chloride (PAC) is one of the most consequential decisions an effluent treatment plant (ETP), water treatment plant (WTP), or municipal water utility operator faces. Both of these chemicals function as primary coagulants designed to clarify turbid, cloudy water by clumping together microscopic suspended impurities [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":68,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-66","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>lum vs PAC: Which Coagulant to Use | Velonex<\/title>\n<meta name=\"description\" content=\"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"lum vs PAC: Which Coagulant to Use | Velonex\" \/>\n<meta property=\"og:description\" content=\"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/\" \/>\n<meta property=\"og:site_name\" content=\"Velonex Chemicals Blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-28T12:10:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-09T05:00:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1408\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"16 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/#\\\/schema\\\/person\\\/e2113bbd4619f413cc3357e9df32b133\"},\"headline\":\"Alum vs PAC (Poly Aluminium Chloride): Which Coagulant Suits Your Plant, and How to Decide With a Jar Test\",\"datePublished\":\"2026-09-28T12:10:35+00:00\",\"dateModified\":\"2026-10-09T05:00:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/\"},\"wordCount\":3393,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png\",\"articleSection\":[\"blogs\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/\",\"url\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/\",\"name\":\"lum vs PAC: Which Coagulant to Use | Velonex\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png\",\"datePublished\":\"2026-09-28T12:10:35+00:00\",\"dateModified\":\"2026-10-09T05:00:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/#\\\/schema\\\/person\\\/e2113bbd4619f413cc3357e9df32b133\"},\"description\":\"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png\",\"contentUrl\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png\",\"width\":1408,\"height\":768},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/alum-vs-pac-coagulant\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alum vs PAC (Poly Aluminium Chloride): Which Coagulant Suits Your Plant, and How to Decide With a Jar Test\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/\",\"name\":\"Velonex Chemicals Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.velonexchemicals.com\\\/blog\\\/#\\\/schema\\\/person\\\/e2113bbd4619f413cc3357e9df32b133\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/velonexchemicals.com\\\/blog\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"lum vs PAC: Which Coagulant to Use | Velonex","description":"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/","og_locale":"en_US","og_type":"article","og_title":"lum vs PAC: Which Coagulant to Use | Velonex","og_description":"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.","og_url":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/","og_site_name":"Velonex Chemicals Blog","article_published_time":"2026-09-28T12:10:35+00:00","article_modified_time":"2026-10-09T05:00:06+00:00","og_image":[{"width":1408,"height":768,"url":"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"16 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#article","isPartOf":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/"},"author":{"name":"admin","@id":"https:\/\/www.velonexchemicals.com\/blog\/#\/schema\/person\/e2113bbd4619f413cc3357e9df32b133"},"headline":"Alum vs PAC (Poly Aluminium Chloride): Which Coagulant Suits Your Plant, and How to Decide With a Jar Test","datePublished":"2026-09-28T12:10:35+00:00","dateModified":"2026-10-09T05:00:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/"},"wordCount":3393,"commentCount":0,"image":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#primaryimage"},"thumbnailUrl":"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png","articleSection":["blogs"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/","url":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/","name":"lum vs PAC: Which Coagulant to Use | Velonex","isPartOf":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#primaryimage"},"image":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#primaryimage"},"thumbnailUrl":"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png","datePublished":"2026-09-28T12:10:35+00:00","dateModified":"2026-10-09T05:00:06+00:00","author":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/#\/schema\/person\/e2113bbd4619f413cc3357e9df32b133"},"description":"Alum is cheaper, PAC works over a wider pH and makes less sludge. Compare both, then confirm with a jar test. Chennai supply.","breadcrumb":{"@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#primaryimage","url":"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png","contentUrl":"https:\/\/www.velonexchemicals.com\/blog\/wp-content\/uploads\/2026\/09\/Gemini_Generated_Image_n3mecjn3mecjn3me-1.png","width":1408,"height":768},{"@type":"BreadcrumbList","@id":"https:\/\/www.velonexchemicals.com\/blog\/alum-vs-pac-coagulant\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.velonexchemicals.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Alum vs PAC (Poly Aluminium Chloride): Which Coagulant Suits Your Plant, and How to Decide With a Jar Test"}]},{"@type":"WebSite","@id":"https:\/\/www.velonexchemicals.com\/blog\/#website","url":"https:\/\/www.velonexchemicals.com\/blog\/","name":"Velonex Chemicals Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.velonexchemicals.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.velonexchemicals.com\/blog\/#\/schema\/person\/e2113bbd4619f413cc3357e9df32b133","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da369236127ed9b92a3ae05730e3f0dbff052cb968a85b5f88e4b2577369eee2?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/velonexchemicals.com\/blog"]}]}},"_links":{"self":[{"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/posts\/66","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/comments?post=66"}],"version-history":[{"count":1,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/posts\/66\/revisions"}],"predecessor-version":[{"id":69,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/posts\/66\/revisions\/69"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/media\/68"}],"wp:attachment":[{"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/media?parent=66"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/categories?post=66"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.velonexchemicals.com\/blog\/wp-json\/wp\/v2\/tags?post=66"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}